ProdcutLines

  • Options

On-Line UPS AHA-H 103HR/303HR LED

big_pic

Features

  • Multiple Microprocessor design base
  • Detachable control panel with LCD
  • Unity input power factor and wide input range
  • Robust design with output transformer
  • True sine-wave double conversion on-line UPS
  • DC start and automatic self-diagnostic function
  • Capacity of battery unlimited and alarm silent
  • RS232 communication port and built-in SNMP slot
  • High efficiency design to save electricity
  • Low heat dissipation in long term operation
  • Designed to operate under harsh environment
  • Enhanced protections against lighting surges, disturbances etc..

Overview

The Vesta series provides comprehensive protection and high power density in small and economic package. Compared to traditional UPS towers of the same size, Vesta UPS is more compact and offers greater comprehensive power protection against surges and spikes. Equipped with a voltage stabilizer, this UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office applicatio
Specifications

Model (LED Series)

AHA-103HR

AHA-203HR

AHA-303HR

Input

Capacity

1KVA/700W

2KVA/1400W

3KVA/2100W

Phase

Single Phase

Nominal Voltage

220Vac/110Vac

Voltage Range

160-300Vac(70%-100%load),140-300Vac (50%-70% load), 118-300Vac (0%-50% load)

Frequency

50Hz / 60Hz 4Hz

Power Factor

0.95

0.97

Output

Voltage

220VAC 2% (230V or 240V re-settable via LCD panel) 110V 2% (100V,115V or 120V re-settable via LCD panel )

Frequency

Synchronized ( Line mode); 50Hz or 60Hz +/-0.5% (Battery mode)

Wave-form

True Sine wave

Distortion

Tower

3% (linear load)
6% non-linear load)

4% (linear load)
7% non-linear load)

Rack

4% (linear load) , 7% non-linear load)

Overload Capacity

105%~125% : 30 sec, UPS go bypass.
>125% : UPS go Bypass immediately. Load reduce to
90%, UPS go back to inverter mode automatically.
> 150%: 300ms,UPS shutdown.

Crest Ratio

3: 1

Battery

DC Voltage

36V

96V

Capacity

12V / 7Ah X 3 pcs

12V / 7Ah X 8pcs

Back-up Time

5min.

9min.

5min.

Charger

Built-In /Option

1Amp/8Amp

1Amp/8Amp

Recharging Time

5 hrs to 90%

Bypass

Automatic

Overload or UPS fault

 

By setting

Voltage Range: 176~256V20V (Re-settable via LCD panel)

Transfer Time

0 ms( 2.5ms inverter to bypass)

Indicator

LCD (Series)

UPS status, I/P&O/P Voltage & Frequency ,Load %, Battery Voltage, Battery Capacity % ,Temperature, Model Spec., Event Log.
LED: Normal (Green), Warning (Yellow), Fault (Red)

LED (Series)

Normal (Green), Bypass(Yellow), Battery Low (Yellow), Inverter (Green), Load% (5 LEDs), Battery % (5 LEDs), Fault(Red)

Outlet

Tower

NEMAx3pcs
or IEC320x4pcs

NEMAx6pcs
or IEC320x6pcs

NEMAx6pcs
or IEC320x3+ TBx1

Rack

NEMAx4pcs
or IEC320x4pcs

NEMAx2+TBx1
or IEC320x4pcs

NEMAx2+TBx1
or IEC320x1+TBx1

Audible
Alarm

Battery Mode

Beeping every 4 seconds (re-settable)

Battery Low

Beeping every seconds

Overload

Beeping twice per second

Fault

Beeping Continuously

Interface

RS-232 Interface

UPSilon2000 monitoring software for Windows all, Unix systems and Novell.

Multi-Interface Slot

SNMP card, AS 400, Dry Contact, USB Selectable

Network

Surge Protection

RJ45 I/O port for Network or RJ 11 for Fax / Modem

Parallel

N/A

Environment

Temperature

0~40J; 32~104K

Humidity

0-95% non-condensing

Acoustic Noise

45 dBA ( at 1M )

50 dBA ( at 1 M)

Physical

Weight (w/o Battery

6.5 kgs (Tower)
8.0 kgs (Rack)

13.5kgs (Tower)
9.5 kgs ( (Rack)

14.5kgs(Tower)
10.5kgs (Rack)

Weight (w/ Battery)

15 kgs (Tower)
15.5 kgs (Rack)

34 kgs (Tower)
N/A (Rack)

35 kgs (Tower)
N/A (Rack)

Dimension W*H*D

Tower

160 x 220 x 400 mm

200 x 352 x 450 mm

Rack

440 x 88 x 465mm (Rack)

Color

White or Black

*Tower Series: AHA-H, Rack Series: AHA-HR

*Rack Battery Bank (2U) is available for 8pcs (1 set) 12V/7Ah and 9pcs (3 sets) 12V/7Ah batteries.